Intrinsically Safe
Pressure switches - Intrinsically safe ATEX Exia certified for use in Category 1 (Zone 0) hazardous areas.
Guardian Range – Industry standard
- Intrinsically safe certification ATEX CE Ex II1G Exia IIC
T6 Ta -50 to +78°C, T5 Ta -50 to +93°C, T4 Ta -50 to +128°C - Black anodised aluminium alloy or 316 st. steel housing, IP67 rated.
- Single or two level switch points.
- M20 electrical entry.
- Proven and documented SIL 2 IEC 61508 suitability.
- Adjustable deadband & manual reset pushbutton option
Guardian Intrinsically Safe Pressure Switch
Titan Range
- Intrinsically safe certification ATEX CE Ex II1G Exia IIC
T6 Ta -50 to +78°C, T5 Ta -50 to +93°C, T4 Ta -50 to +128°C.
CE Ex II1D ExiaD 20 IP66 T200°C Ta -50 to +70°C - Black anodised aluminium alloy or 316 stainless steel housing, IP66 rated.
- 1 x SPDT microswitch or 2 x SPDT microswitches (simultaneous operation).
- Integral terminal block via M20 electrical entry.
- Proven and documented SIL 2 IEC 61508 suitability.
- Circuit monitoring resistors option.
- GOST (R) option.
Titan Intrinsically Safe Pressure Switch
Argus Range – OEM suitability
- Intrinsically safe' certification ATEX CE Ex II1G EExia IIC
T6 Ta -50 to +78°C, T5 Ta -50 to +93°C, T4 Ta -50 to +128°C. - PPS (engineering polymer) or 316 stainless steel housing, rated IP67.
- 1 x SPDT microswitch or 2 x SPDT microswitches (simultaneous operation).
- DIN 43650 connector or integral terminal block via M20 entry or flying lead with M20 or ½" NPT male for direct connection to junction box.
- Proven and documented SIL 2 IEC 61508 suitability.
- Circuit monitoring resistors option.
Argus EExia Pressure Switch
Perseus Range
- ATEX CEII1G Exia IIC
T6 Ta = -50 to +78°C & T5 Ta = -50 to +93°C & T4 Ta = -50 to +128°C
II1D ExiaD 20 IP67 T200°C Ta = -50 to 70°C - Single or dual microswitch option
- Calibrated adjustment scale
- Black anodised aluminium switchcase to IP67 standards
- Proven and documented SIL 2 IEC 61508 suitability.
Perseus EExia Pressure Switch