Intrinsically Safe
Temperature switches - Intrinsically safe ATEX EExia certified for use in Category 1 (Zone 0) hazardous areas.
Guardian Range – Industry standard
- Certification ATEX CE Ex II1G EExia IIC
- T6 Ta -50 to +78°C, T5 Ta -50 to +93°C, T4 Ta -50 to +128°C
- Single or dual settings
- Stainless steel or black anodised aluminium case to IP66/67
- M20 electrical connection
- Thermowell lengths from 38 to 1200mm
- Capillary option 2 to 15 metres, 100mm to 600mm thermowells
- Proven and documented SIL 2 IEC 61508 suitability
- Manual reset option
- Alternative microswitches
Guardian Intrinsically Safe Temperature Switch
Titan Range – Extreme arduous applications
- Certification ATEX CE Ex II1GD EExia IIC
- T6 Tamb -50 to +78°C, T5 Tamb -50 to +93°C, T4 Tamb -50 to +128°C
- Single or simultaneous dual settings
- Stainless steel or black anodised case to IP66
- Integral terminal block via M20 electrical connection
- Thermowell lengths from 38 to 1200mm
- Capillary option 2 to 15 metres, 100mm to 600mm thermowells
- Proven and documented SIL 2 IEC 61508 suitability
- Circuit monitoring resistors option
- Ministry of Defence approved
Titan Intrinsically Safe Temperature Switch
Argus Range – OEM Suitability
- Certification ATEX CE Ex II1G EExia IIC
- T6 Ta -50 to +78°C, T5 Ta -50 to +93°C, T4 Ta -50 to +128°C
- Single or simultaneous dual settings
- PPS (engineering polymer) or stainless steel case to IP67
- DIN 43650 connector or integral terminal block via M20 entry
- Thermowell lengths from 100mm to 600mm.
- Capillary lengths 2 to 15 metres.
- Proven and documented SIL 2 IEC 61508 suitability.
Argus Intrinsically Safe Remote Mount Temperature Switch