Sentinel Range
Technical Description
Switchcase and covers: Black anodised aluminium switchcase with a 316 stainless steel mounting plate.
Power supply:
- Option 1: 2x AA lithium batteries which will give a minimum of 12 months standby/indication or 1,000,000 relay operations.
- Option 2: 24VDC 20%/-15% auxiliary supply with 4-20mA loop output option.
Outputs: The switch has two output relays each with a change over contact.
Rating: 5A @ 30VDC and 250VAC.
Max. switch voltage: 125VDC and 380VAC.
Max. switch power: 240W, 2000VA.
Min. contact load: 10mA @ 5VDC
Contact material: Gold clad silver palladium.
Initial contact resistance: 30mOhm
Relay contact electrical life: 100,000 operations minimum at max. rated load
Relay contact mechanical life: 50 x 10 ops minimum.
4-20 mA loop: Supply voltage 20-30VDC.
Load resistance: 0-500ohm.
Set point adjustment: 0-100% continuously variable.
Accuracy: +/-1% LSD
Thermal drift: 0.04% per °C
Sample rate: Approx. twice per second.
Electrical Conduit Entry: Two M20 x 1.5 straight entry. Adaptors are available
Electrical Connections: Screwed terminals suitable for cable up to 2.5 mm2.
Environmental Protection: Switches have been tested to IP66 in accordance with BS EN 60529:1992.
Vibration and shock parameters: Switches were subjected to Lloyds Register Type Approval System Test Specification No.1 Clause 130 Vibration Test 2 and shock tested to BS EN 60068-2-27:1987
Temperature Limitations:
- Ambient: -10 to +55°C
- Storage: -20 to +60°C